Motor control (MCTRL)

5.11

Braking operation/brake energy management

228

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Proceed as follows to open the dialog for parameterising the brake energy management:

1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the "basic functions" button.
4. Go to the Overviewbasic functions dialog box and click the Brake energy management

button.

Short overview of the relevant parameters:

Parameter

Info

Lenze setting

Value Unit

C00173

Mains voltage

3ph 400 V / 1ph 230 V

C00175

Brake energy management

R_Brake (brake resistance)

Brake resistor

C00133

Brake resistor utilisation

- %

C00129

Brake resistance value

39.0 Ohm

C00130

Rated brake resistor power

100 W

C00131

Thermal capacity - brake resistor

10.0 kWs

C00174

Reduced brake chopper threshold

0 V

C00572

Threshold - brake resist. overload

100 %

C00574

Resp. to brake resist. overtemp.

No response

Inverter motor brake

C00987

Inverter motor brake: nAdd

80 rpm

C00988

Inverter motor brake: PT1 filter time

0.0 ms

Highlighted in grey = display parameter

Advertising