C02223 | ls_writeparamlist: imax/m controller gain, C02225 | ls_writeparamlist: vp current controller, C02223/1 – Lenze 8400 StateLine User Manual

Page 794: C02223/2, C02223/3, C02223/4, C02223/5, C02223/6, C02223/7, C02223/8

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02223

794

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02223

C02224

C02225

Parameter | Name:

C02223 | LS_WriteParamList: Imax/M controller gain

Data type: UNSIGNED_16

Index: 22352

d

= 5750

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

100.00

Subcodes

Lenze setting

Info

C02223/1

0.25

LS_WriteParamList

: c73_s1_val1

C02223/2

0.25

LS_WriteParamList

: c73_s1_val2

C02223/3

0.25

LS_WriteParamList

: c73_s1_val3

C02223/4

0.25

LS_WriteParamList

: c73_s1_val4

C02223/5

1.25

LS_WriteParamList

: c73_s2_val1

C02223/6

1.25

LS_WriteParamList

: c73_s2_val2

C02223/7

1.25

LS_WriteParamList

: c73_s2_val3

C02223/8

1.25

LS_WriteParamList

: c73_s2_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02224 | LS_WriteParamList: Imax/M controller reset time

Data type: UNSIGNED_16

Index: 22351

d

= 574F

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

ms

9990

Subcodes

Lenze setting

Info

C02224/1

65 ms

LS_WriteParamList

: c74_s1_val1

C02224/2

65 ms

LS_WriteParamList

: c74_s1_val2

C02224/3

65 ms

LS_WriteParamList

: c74_s1_val3

C02224/4

65 ms

LS_WriteParamList

: c74_s1_val4

C02224/5

30 ms

LS_WriteParamList

: c74_s2_val1

C02224/6

30 ms

LS_WriteParamList

: c74_s2_val2

C02224/7

30 ms

LS_WriteParamList

: c74_s2_val3

C02224/8

30 ms

LS_WriteParamList

: c74_s2_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02225 | LS_WriteParamList: Vp current controller

Data type: UNSIGNED_16

Index: 22350

d

= 574E

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

V/A

500.00

Subcodes

Lenze setting

Info

C02225/1

7.00 V/A

LS_WriteParamList

: c75_val1

C02225/2

7.00 V/A

LS_WriteParamList

: c75_val2

C02225/3

7.00 V/A

LS_WriteParamList

: c75_val3

C02225/4

7.00 V/A

LS_WriteParamList

: c75_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100