Parameter | Name:

C00635 | L_NSet_1: nMaxLimit

Data type: INTEGER_16

Index: 23940

d

= 5D84

h

The

L_NSet_1

FB: Maximum speed setpoint for speed setpoint limitation

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 199.99 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00636 | L_NSet_1: nMinLimit

Data type: INTEGER_16

Index: 23939

d

= 5D83

h

The

L_NSet_1

FB: Minimum speed setpoint for speed setpoint limitation

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 -199.99 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00637 | L_NSet_1: Output blocking zones

Data type: INTEGER_16

Index: 23938

d

= 5D82

h

The

L_NSet_1

FB: Speed setpoint is displayed after being processed by blocking zone function

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00638 | L_NSet_1: Output ramp rounding

Data type: INTEGER_16

Index: 23937

d

= 5D81

h

The

L_NSet_1

FB: Speed setpoint is displayed after being processed by PT1 filter function

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00639 | L_NSet_1: Output additional value

Data type: INTEGER_16

Index: 23936

d

= 5D80

h

The

L_NSet_1

FB: Additional speed setpoint is displayed after being processed by the ramp generator

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100