5.8.4.1

Optimise current controller

An optimisation of the current controller is sensible since the two control parameters gain (

C00075

)

and reset time (

C00076

) depend on the required maximum current and the set switching

frequency.

• Gain and reset time can be calculated as per the following formulae:

Note!

An optimisation of the current controller should generally be carried out unless a power-

adapted standard motor is used or the motor has been selected from the motor

catalogue of the »Engineer«!

Parameter

Info

Lenze setting

Value Unit

C00075

Vp current controller

7.00 V/A

C00076

Ti current controller

10.61 ms

V

p

= Current controller gain (

C00075

)

T

i

= Current controller reset time (

C00076

)

L

ss

= Motor stator leakage inductance (

C00085

)

R

s

= Motor stator resistance (

C00084

)

T

E

= Equivalent time constant (= 500 μs)

V

p

L

ss

H

[ ]

T

E

s

[ ]

----------------

=

T

i

L

ss

H

[ ]

R

s

Ω

[ ]

----------------

=