17.1.11.3 Function 3: nIn1 < nIn2
This function serves, for instance, to implement the comparison "actual speed is lower than a limit
value" (n
act
< n
x
) for one direction of rotation.
[17-8] Function 3: Switching performance
Functional sequence
1. If the value at nIn1_a falls below the value at nIn2_a, bOut changes from FALSE to TRUE.
2. Only if the signal at nIn1_a exceeds the value of nIn2_a - hysteresis again, bOut changes back
from TRUE to FALSE.
[17-9] Function 3: Example
: Hysteresis
TRUE
FALSE
bOut
nIn2_a
nIn1_a
: Hysteresis
nIn1_a
nIn2_a
TRUE
FALSE
bOut
t
t