2 saving the oscillogram, Saving the oscillogram, Saving the oscillogram ( 484) – Lenze 8400 StateLine User Manual

Page 484: 10 oscilloscope function

Advertising
background image

10

Oscilloscope function

10.4

Managing oscillograms (measured data sets)

484

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.4.2

Saving the oscillogram

After the variables to be recorded have been selected and the required settings have been entered,

you can save the configuration and recording, if already executed, for future use in the project or

export them to a file.

How to save the data set in the project:

1. Click the

icon in the oscilloscope toolbar.

• The Save data set dialog box appears.

2. Enter a name in the Name of the data set to be stored input field.
3. Click Filing in the project.

• The dialog box is closed and the current data set is filed in the project.

How to export the data set to a file:

1. Click the

icon in the oscilloscope toolbar.

• The Save data set dialog box appears.

2. Enter a name in the Name of the data set to be stored input field.
3. Click the Export to file button.
4. Specify the filing folder and the file name of the data set to be stored in the Save as dialog

box.

5. Click Save.

• The dialog box is closed and the current data set is saved.

Note!

The reuse of a saved configuration is only reasonable for controllers of the same type, as

otherwise due to a scaling of the oscilloscope channels that is not adapted, incorrect

values are displayed!

Note!

The data set is only saved if the entire project is saved!

Advertising