Ck16: time overflow manual control, Error m, Xx.0184.00005 – Lenze 8400 StateLine User Manual

Page 468: Xx.0184.00064, Xx.0145.00052, Xx.0400.00009, Xx.0400.00016, 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.9

Error messages of the operating system

468

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

dF52: BuCcr error [xx.0145.00052]

Ck15: Error status sign. brake [xx.0184.00005]

Ck16: Time overflow manual operation [xx.0184.00064]

dH09: EEPROM power section [xx.0400.00009]

dH10: Fan failure [xx.0400.00016]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Mains switching

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The status monitoring of the holding brake control

has tripped.

• Check configuration of the bMBrakeApplied input for

status detection of the brake (via a switching contact

at the brake).

• Check wiring/function of the switching contact.

• Adapt waiting time (

C02589/3

).

• Deactivate status monitoring (via bit 5 in

C02582

).

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

PC manual control: The connection monitoring has

tripped.

• The online connection between the PC and the

controller has been interrupted for a longer period of

time than the timeout set in

C00464/1

.

• Check communication link between PC and

controller.

• Check voltage supply/function of the controller.

• Adjust the timeout (

C00464/1

).

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

Setting:

C00566

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device fan has failed.

Possible causes:

• The short-circuit check of the fan connection has

tripped.

• The speed monitoring of the fan has tripped.

• Check the fan for short-circuit.

• Clean the fan.

Advertising