C00490 | position encoder selection, C00495 | speed sensor selection, C00496 | encoder evaluation method digin12 – Lenze 8400 StateLine User Manual

Page 696: C00497 | filter time constant, C00497, C00495, This setting is, C00497/1, C00496, C00490

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00490

696

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00490

C00495

C00496

C00497

Parameter | Name:

C00490 | Position encoder selection

Data type: UNSIGNED_8

Index: 24085

d

= 5E15

h

From version 12.00.00

Selection of the procedure of generating the actual position

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

0 No sensor: nSpeedSetValue_a

The position signal dnMotorPosAct_p is derived from the

speed setpoint nSpeedSetValue_a.

10 Encoder selection C495 or

nVoltageAngleAct_a

The position signal dnMotorPosAct_p is either calculated

from the set speed feedback (for

C00495

> 0) or from the

speed signal nMotorSpeedAct_v (for

C00495

= 0).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00495 | Speed sensor selection

Data type: UNSIGNED_8

Index: 24080

d

= 5E10

h

Selection of the feedback system for the actual speed for motor control and display

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

0 No sensor

No sensor available for the actual speed detection

1 Sensor signal FreqIn12

Speed sensor signal is fed via the digital DI1 and DI2

inputs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00496 | Encoder evaluation method DigIn12

Data type: UNSIGNED_8

Index: 24079

d

= 5E0F

h

From version 03.00.00

Encoder/feedback system

Selection list

(Lenze setting printed in bold)

Info

1 Low-resolution encoder (StateLine)

High-precision procedure for low-resolution encoders

(<=128 increments)

3 Edge-counting procedure

Simple edge counting procedure with adjustable

scanning time (

C00425

)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00497 | Filter time constant

Data type: UNSIGNED_16

Index: 24078

d

= 5E0E

h

From version 03.00.00

Encoder/feedback system

Setting range

(min. value | unit | max. value)

0.0

ms

500.0

Subcodes

Lenze setting

Info

C00497/1

1.0 ms

FreqIn12: Encoder filter time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10