2 terminals 2, Terminals 2, Control mode – Lenze 8400 StateLine User Manual
Page 371: 7technology applications
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
371
7
Technology applications
7.4
TA "Switch-off positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.3.2
Terminals 2
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_SwitchPos.bDriveFail
X4/RFR
LA_SwitchPos: bFailReset
X3/A1U
LA_SwitchPos.nMainSetValue_a *
X4/DI1
LA_SwitchPos: bJogCtrlStop1
X3/A1I
-
X4/DI2
LA_SwitchPos: bJogCtrlStop2
X3/O1U
-
X4/DI3
LA_SwitchPos: bRLQCw
* 10 V ≡ 100 % reference speed (
LA_SwitchPos: bJogCtrlInputSel1
X4/DI4
LA_SwitchPos: bRLQCcw
X4/DO1
LA_SwitchPos.bDriveReady
LA_SwitchPos: bJogCtrlInputSel2
+
=
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
COM
NC
NO
X101
CG
C
L
CH
X1
Stop function 1
Stop function 2
CW rotat. quick stop / selection: switch-off pos. 1
CCW rotat. quick stop / selection: switch-off pos. 2
External
supply
24 V DC
Speed setpoint
Controller enable / reset error