3 led status displays for the system bus, Led status displays for, The system bus ( 494) – Lenze 8400 StateLine User Manual

Page 494: 11 system bus "can on board

Advertising
background image

11

System bus "CAN on board"

11.3

LED status displays for the system bus

494

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Example: Setting of the node address 23

11.3

LED status displays for the system bus

Controller is not (yet) active on the system bus

Controller is active on the system bus

• LED "CAN-RUN" signals the CANopen state:

• LED "CAN-ERR" signals a CANopen error:

DIP switch

64

32

16

8

4

2

1

Switch position

OFF

OFF

ON

OFF

ON

ON

ON

Value

0

0

16

0

4

2

1

Node address

= Sum of the values = 16 + 4 + 2 + 1 = 23

Information about the status of the system bus can be obtained quickly via

LED displays "CAN-RUN" and "CAN-ERR" on the front of the controller.
The meaning can be seen from the tables below.

LED display

Meaning

(CAN-ERR is permanently lit)

Controller is not active on the system bus / Bus Off

(CAN-RUN and CAN-ERR flicker)

Automatic detection of baud rate is active

LED display

CANopen state

(CAN-RUN is blinking every 0.2 seconds)

Pre-Operational

(CAN-RUN is permanently lit)

Operational

(CAN-RUN is blinking every second)

Stopped

LED display

CANopen error

(CAN-ERR is blinking once, then off for 1 second)

Warning Limit reached

(CAN-ERR is blinking twice, then off for 1 second)

Node Guard Event

(CAN-ERR is blinking three times, then off for 1 second)

Sync Message Error

(only possible in the "Operational" state)

CAN-RUN

CAN-ERR

DRV-RDY

DRV-ERR