Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

79

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.3

Save all parameter sets

If parameter settings are changed in the controller, those changes will be lost after mains switching

of the controller unless the settings have been saved explicitly.
The

C00002/11

= "1: On / start" device command saves the current parameter settings safe against

mains failure to the memory module of the controller.

How to save the parameter settings to the memory module:
Execute the "Save all parameter sets" device command:

C00002/11

= "1: On / start"

The storage process may take a couple of seconds. After the device command has been

called in

C00002/11

, dynamic status information ("Work in progress 20%"  "Work in

progress 40%"  "Work in progress 60%", etc.) is returned.

Tip!

• This device command can also be activated via the

icon in the Toolbar.

• The "

Load Lenze setting

" device command (

C00002/1

= "1: On / start") resets the

parameter settings to the delivery status of the device.

Notes on execution time
The execution time of this device command depends on the communication module used. If - in

addition to the device-internal time monitoring - a monitoring of the execution time is to be

implemented for this device command in a higher-level control, the monitoring time has to be 2 ...

3 times higher than the times specified in the following table:

Note!

When the device is switched on, all parameters are automatically loaded from the

memory module to the main memory of the controller.
Observe the following to avoid data inconsistencies which cause errors when the

parameters are loaded from the memory module:
During the storage process:

• Do not switch off the supply voltage!
• Do not remove the memory module from the device!

The controller is currently provided with one data record for all parameters, i.e. every

parameter has a value. Several data records per controller are in preparation.

Communication module used

Typical execution time

StateLine C

HighLine C

TopLine C

Without communication module

2.0 s

2.5 s

2.5 s

PROFIBUS® or INTERBUS

3.5 s

3.5 s

4.0 s

EtherCAT®, PROFINET® or EtherNet/IP™

4.5 s

4.5 s

4.5 s

Ethernet POWERLINK

11.0 s

11.0 s

11.0 s