C02236 | ls_writeparamlist: rated motor speed, C02233/1, C02233/2 – Lenze 8400 StateLine User Manual

Page 797: C02233/3, C02233/4, C02234/1, C02234/2, C02234/3, C02234/4, C02236/1

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

797

15

Parameter reference

15.2

Parameter list | C02233

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02233

C02234

C02236

Parameter | Name:

C02233 | LS_WriteParamList: Motor stator resistance

Data type: UNSIGNED_32

Index: 22342

d

= 5746

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

mOhm

200000

Subcodes

Lenze setting

Info

C02233/1

330 mOhm

LS_WriteParamList

: c84_val1

C02233/2

330 mOhm

LS_WriteParamList

: c84_val2

C02233/3

330 mOhm

LS_WriteParamList

: c84_val3

C02233/4

330 mOhm

LS_WriteParamList

: c84_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02234 | LS_WriteParamList: Motor stator leakage inductance

Data type: UNSIGNED_16

Index: 22341

d

= 5745

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

mH

650.00

Subcodes

Lenze setting

Info

C02234/1

3.50 mH

LS_WriteParamList

: c85_val1

C02234/2

3.50 mH

LS_WriteParamList

: c85_val2

C02234/3

3.50 mH

LS_WriteParamList

: c85_val3

C02234/4

3.50 mH

LS_WriteParamList

: c85_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02236 | LS_WriteParamList: Rated motor speed

Data type: UNSIGNED_16

Index: 22339

d

= 5743

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

50

rpm

60000

Subcodes

Lenze setting

Info

C02236/1

1460 rpm

LS_WriteParamList

: c87_val1

C02236/2

1460 rpm

LS_WriteParamList

: c87_val2

C02236/3

1460 rpm

LS_WriteParamList

: c87_val3

C02236/4

1460 rpm

LS_WriteParamList

: c87_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising