6i/o terminals – Lenze 8400 StateLine User Manual

Page 263

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

263

6

I/O terminals

6.1

Digital terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the parameters for the digital terminals:

Related topics:

Configuring exception handling of the output terminals

( 288)

User-defined terminal assignment

( 289)

Parameter

Info

Lenze setting

Value Unit

C00115/1

Fkt. DI 1/2 10kHz

Change function assignment ( 264)

0: DI1=In1 / DI2=In2

Digital inputs DI1 ... DI4

C00114

DigInX: Inversion

Bit coded

C02830/1...4

DI1...DI4: Entprellzeit

1: 0.25

C00443/1

DIx: Terminal level

-

C00443/2

DIx: Output level

-

Digital output DO1

C00118

DigOutX: Inversion

Bit coded

C00423/3

DO1 ON delay

0.000 s

C00423/4

DO1 OFF delay

0.000 s

C00444/1

DOx: Input level

-

C00444/2

DOx: Terminal level

-

Relay output

C00423/1

Relay ON delay

0.000 s

C00423/2

Relay OFF delay

0.000 s

Digital outputs - terminal configuration

C00621/1

LS_DigitalOutput:bRelay

1001: LA_nCtrl_bDriveFail

C00621/2

LS_DigitalOutput:bOut1

1000: LA_nCtrl_bDriveReady

Highlighted in grey = display parameter