C02295/1, C02295/2, C02295/3 – Lenze 8400 StateLine User Manual

Page 810: C02295/4, C02296/1, C02296/2, C02296/3, C02296/4, C02297/1, C02297/2

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02295

810

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02295

C02296

C02297

Parameter | Name:

C02295 | LS_WriteParamList: Flying restart fct.: Activation

Data type: UNSIGNED_8

Index: 22280

d

= 5708

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Selection list

0 Off
1 On

Subcodes

Lenze setting

Info

C02295/1

0: Off

LS_WriteParamList

: c990_val1

C02295/2

0: Off

LS_WriteParamList

: c990_val2

C02295/3

0: Off

LS_WriteParamList

: c990_val3

C02295/4

0: Off

LS_WriteParamList

: c990_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02296 | LS_WriteParamList: Flying restart fct.: process

Data type: UNSIGNED_16

Index: 22279

d

= 5707

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Selection list

0 0...+n | Start: +10 Hz
1 -n...0 | Start: -10 Hz
2 -n...+n | Start: +10 Hz
3 -n...+n | Start: -10 Hz
4 -n...+n | Start: Cx992

Subcodes

Lenze setting

Info

C02296/1

2: -n...+n | Start: +10 Hz

LS_WriteParamList

: c991_val1

C02296/2

2: -n...+n | Start: +10 Hz

LS_WriteParamList

: c991_val2

C02296/3

2: -n...+n | Start: +10 Hz

LS_WriteParamList

: c991_val3

C02296/4

2: -n...+n | Start: +10 Hz

LS_WriteParamList

: c991_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02297 | LS_WriteParamList: Flying restart: Start frequency

Data type: INTEGER_16

Index: 22278

d

= 5706

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

-200

Hz

200

Subcodes

Lenze setting

Info

C02297/1

10 Hz

LS_WriteParamList

: c992_val1

C02297/2

10 Hz

LS_WriteParamList

: c992_val2

C02297/3

10 Hz

LS_WriteParamList

: c992_val3

C02297/4

10 Hz

LS_WriteParamList

: c992_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1