8 mci, 7technology applications – Lenze 8400 StateLine User Manual

Page 377

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

377

7

Technology applications

7.4

TA "Switch-off positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.3.8

MCI

Process data assignment for fieldbus communication

( 378)

Connection

Assignment

Connection

Assignment

X101/NC-NO

LA_SwitchPos.bDriveFail

X4/RFR

LA_SwitchPos: bFailReset

X3/A1U

LA_SwitchPos.nAuxSetValue_a *

X4/DI1

LA_SwitchPos: bJogCtrlStop1

X3/A1I

-

X4/DI2

LA_SwitchPos: bJogCtrlSlowDown1

X3/O1U

-

X4/DI3

LA_SwitchPos: bJogCtrlStop2

* 10 V ≡ 100 % reference speed (

C00011

)

X4/DI4

LA_SwitchPos: bJogCtrlSlowDown2

X4/DO1

LA_SwitchPos.bDriveReady

Note!

You must set the setpoint arithmetic in

C00190

to "1: NOut = NSet + NAdd" so that the

additional speed setpoint selected via the analog input A1U has an additive effect.

=

X4

DI3

DI2

DI4

GIO

24I

DI1

RFR

24E

+

+

+

+

X3

AR
A1U

GA

A1I

DO1

O1U

COM

NC

NO

X101

LP_MciIn

wCtrl

wIn2

wIn3...16

DriveControl

MainSetValue

-

LP_MciOut

wState

wOut2

wOut3

DriveControlStatus

MotorSpeedAct

GPSignalOut1

wOut4...16 -

CG

C

L

CH

X1

External

supply

24 V DC

Additional speed setpoint

Controller enable / reset error

Stop function 2

Stop function 1

Selection of pre-switch off 1

Selection of pre-switch off 2