10 oscilloscope function – Lenze 8400 StateLine User Manual

Page 480

Advertising
background image

10

Oscilloscope function

10.3

Operation

480

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Selection of the horizontal display position
The Position input field can be used to change the horizontal display position.

• The position value can be directly entered into the input field or selected using the arrow

buttons.

• When the arrow buttons are used and the <Ctrl> key is pressed, you can increase the step size

to accelerate the shift.

Subsequently changing the time base
Change the time base to stretch or compress measurements that have already been completed.

Zoom function

Go to the oscilloscope toolbar and click the

icon to activate the zoom function.

Zoom function

Procedure

Zoom selection

Hold down the left mouse button and draw the oscillogram section to be

zoomed:

• While being drawn, the selection is shown with a frame.

• When the left mouse button is released, the selection is zoomed in

the oscillogram.

Horizontal/vertical shift of

selection

Hold down the left and right mouse button and move the mouse pointer

on the scale to shift the selection accordingly.

With a three-button mouse, you can use the mouse button in the

middle.

Horizontal stretching

On the horizontal scale:

Hold down the left mouse button and move the mouse pointer to the

left to stretch the shown selection from the right edge.

Hold down the right mouse button and move the mouse pointer to the

right to stretch the shown selection from the left edge.

Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Vertical stretching

On the vertical scale:

Hold down the left mouse button and move the mouse pointer to the

bottom to stretch the shown selection from the top.

Hold down the right mouse button and move the mouse pointer to the

top to stretch the shown selection from the bottom.

Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Return to original

representation

Click the right mouse button in the oscillogram to return step by step to

the original representation.