C00670 | l_offsetgainp_1: gain, C00671 | l_offsetgainp_2: gain, C00672 | l_offsetgainp_3: gain – Lenze 8400 StateLine User Manual

Page 726: C00654/1, If the, C00670, C00671, For a simpl, C00672, For a s

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00654

726

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00654

C00670

C00671

C00672

Parameter | Name:

C00654 | Source of diff. setpoint feedforward control

Data type: UNSIGNED_8

Index: 23921

d

= 5D71

h

Selection list

Info

0 nSpeedSetValue_a
1 nSpeedSetValueInertia_a

Subcodes

Lenze setting

Info

C00654/1

0: nSpeedSetValue_a

Source of diff. setpoint feedforward control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00670 | L_OffsetGainP_1: Gain

Data type: INTEGER_32

Index: 23905

d

= 5D61

h

The

L_OffsetGainP_1

FB: Gain as multiplier of the input signal + offset

Setting range

(min. value | unit | max. value)

Lenze setting

-100.0000

100.0000 1.0000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C00671 | L_OffsetGainP_2: Gain

Data type: INTEGER_32

Index: 23904

d

= 5D60

h

The

L_OffsetGainP_2

FB: Gain as multiplier of the input signal + offset

Setting range

(min. value | unit | max. value)

Lenze setting

-100.0000

100.0000 1.0000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C00672 | L_OffsetGainP_3: Gain

Data type: INTEGER_32

Index: 23903

d

= 5D5F

h

The

L_OffsetGainP_3

FB: Gain as multiplier of the input signal + offset

Setting range

(min. value | unit | max. value)

Lenze setting

-100.0000

100.0000 1.0000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000