14

Parameter change-over

14.1

Configuring parameter change-over via the »Engineer« parameterisation dialog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.1.3

Functional settings

14.1.4

Error indication

With every run through the main program, one parameter of the definable parameter list is written

until the parameter list has been executed completely. If an error occurs,

C01083

displays an error

status and

C01084

displays the number of the list entry causing the error (in connection with the

selected value set).

• If several errors occur at the same time, only the first incorrect list entry will be displayed. Hence,

after elimination of the displayed error and another activation, more errors may be displayed.

• The parameter list will always be processed from beginning to end, even if errors occur in the

meantime.

Parameter

Lenze setting

Info

Execute Mode

(

C01082

)

0: by Execute

For writing the parameter list, two modes are

available:

• 0: by Execute (Lenze setting)

The writing of the parameter list is activated by a

FALSE/TRUE edge at the bExecute control input.

• 1: by Input Select

The parameter list is written when the selection

inputs bSelectWriteValue_1 and

bSelectWriteValue_2 are changed and once

during the initialisation of the controller.

Note: If the execute mode changes from "0: by

Execute" to "1: by Input Select", the parameter list

selected by the selection inputs is written once. In

the execute mode "1: by Input Select", the parameter

list then is only written again when a change occurs

on the selection inputs .

Definable parameter list

(

C02200/1

)

1: On

Switch on/off parameter changeover for the

definable parameter list.

Motor data parameter list

(

C02200/2

)

0: Off

Switch on/off parameter changeover for the motor

data parameter list.