7

Technology applications

7.3

TA "actuating drive speed (AC Drive Profile)"

332

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

nBoost_a

INT

Additional setpoint for the motor voltage at speed = 0

• The entire voltage-frequency characteristic is provided with an offset.

• Scaling: 16384 ≡ 1000 V

Stop!

Values selected too high may cause the motor to heat up due to the resulting

current!

nPWMAngleOffset

INT

Additional offset for the electrical angle of rotation

• If a torque is connected, e.g. dynamic acceleration processes can be generated.

• Scaling: ±32767 ≡ ±180 ° angle of rotation

nTorqueMotLim_a

nTorqueGenLim_a

INT

Torque limitation in motor mode and in generator mode (speed mode)

or torque setpoint selection (torque mode)
When "speed mode" is set, the following applies:

• The torque limitation in motor mode and generator mode are determined via

nTorqueMotLim_a.

• The nTorqueGenLim_a input is not effective.

When "torque mode" is set, the following applies:

• The torque setpoint is determined via nTorqueGenLim_a.

• The nTorqueMotLim_a input is not effective.

More notes for both inputs:

• These input signals are directly transferred to the motor control to limit the

controller's maximum torque in motor and generator mode.

• The drive cannot output a higher torque in motor/generator mode than set here.

• The applied values (any polarity) are internally interpreted as absolute values.

• If V/f characteristic control (VFCplus) is selected, limitation is indirectly

performed via a so-called I

max

controller.

• If sensorless vector control (SLVC) or servo control (SC) is selected, limitation has

a direct effect on the torque-producing current component.

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

Torque limits in motor and generator mode:

bSetSpeedCcw

BOOL

Change of direction of rotation

• For instance if a motor or gearbox is fixed laterally reversed to a machine part, but

the setpoint selection should still be executed for the positive direction of

rotation.

Input only effective in case of local control (NetCtrl=0)

FALSE Clockwise rotation (Cw)

TRUE Direction of rotation to the left (Ccw)

bRLQCw

BOOL

Activate clockwise rotation (fail-safe)

• For a detailed functional description see the

L_RLQ

FB.

FALSE Quick stop

TRUE CW rotation

Identifier

Data type

Information/possible settings

n

N

M

N

M

-M

N

-n

N

n

TorqueMotLim

TorqueGenLim

TorqueMotLim

TorqueMotLim

TorqueGenLim