Oc12, Oc12: i2xt brake resistor overload, Oc12: i2xt overload brake resistor – Lenze 8400 StateLine User Manual

Page 458: Xx.0123.00058, Xx.0123.00059, Xx.0123.00060, Xx.0123.00061, Xx.0123.00065, 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.9

Error messages of the operating system

458

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Id3: CINH identification [xx.0123.00058]

Id4: Resistor identification error [xx.0123.00059]

Id7: Motor control does not match motor data [xx.0123.00060]

Id8: Speed encoder has not been set [xx.0123.00061]

oC12: I2xt overload - brake resistor [xx.0123.00065]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has detected controller inhibit during the

motor data identification.

• This cancels the identification process. The Lenze

setting of the motor data is used.

• Do not set controller inhibit during the motor data

identification.

• Do not execute any device function which may

activate controller inhibit.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has recognised that an error has occurred in

the calculation of the motor cable resistance.

• The parameters for cable cross-section and cable

length are implausible.

Enter sensible values for cable cross-section and motor

cable length.

Response (Lenze setting printed in bold)

Setting:

C00571/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

At controller enable, the device has detected that the

motor control type set in

C00006

cannot control the

motor type set.

• Example: Motor nameplate data for an asynchronous

motor have been entered; however, a motor control

type for a synchronous motor is set in

C00006

.

Note:

Since the "VFCplus" control types are able to control

every motor to a certain extent, this error message will

never occur here.

Enter correct motor nameplate data and set a matching

motor control type in

C00006

:

• Motor nameplate data asynchronous motor  motor

control type must be ASM, SLVC or VFCplus servo

control.

• Motor nameplate data synchronous motor  motor

control type must be PSM, SLPSM or VFCplus servo

control.

Response (Lenze setting printed in bold)

Setting:

C00571/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

When being In controller enable status, the device has

detected that a motor control type with feedback has

beent set in

C00006

, but no speed sensor has been set in

C00495

.

Set the speed sensor in

C00495

.

Note: The error can only be reset if the settings in

C00006

and

C00495

match.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Too frequent and too long braking processes.

Check drive dimensioning.