1 oscillation damping voltage range, Oscillation damping voltage range, 5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 217

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

217

5

Motor control (MCTRL)

5.9

Parameterisable additional functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.9.6.1

Oscillation damping voltage range

The oscillation damping voltage range is successfully used with

• unloaded motors (no-load oscillations)
• motors whose rated power deviates from the rated power of the controller.

• e.g. during operation at high switching frequency including the power derating involved.

• operation with higher-pole motors
• operation with special motors
• compensation of resonance in the drive

• At an output frequency of approx. 20 ... 40 Hz, some asynchronous motors can show

resonance which causes current and speed variations and thus destabilise the running

operation.

How to eliminate speed oscillations in no-load operation at speeds with 40 ... 80 % of the

rated speed:

1. Approach the area where the speed oscillations occur.
2. Reduce the speed oscillations by changing

C00234

step by step (increment 1 %).

• The filter time oscillation damping (

C00235

) should not be changed.

3. These can be indicators for smooth running:

• Constant motor current characteristic
• Reduction of the mechanical oscillations in the bearing seat

Parameter

Info

Lenze setting

Value Unit

C00234

Oscillation damping influence

5.00 %

C00235

Oscillation damping filter time

32 ms

Note!

Compensate the resonance during operation with feedback (closed loop, feedback of

n

act

) via the parameters of the slip regulator.

Parameterising the slip regulator

( 158)

Advertising