C01139 | l_transient 1-4: pulse duration, C01350 | acdrive: drive mode, C01350/1 – Lenze 8400 StateLine User Manual

Page 783: 15 parameter reference

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

783

15

Parameter reference

15.2

Parameter list | C01139

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01139

C01350

Parameter | Name:

C01139 | L_Transient 1-4: Pulse duration

Data type: UNSIGNED_16

Index: 23436

d

= 5B8C

h

From version 04.00.00

Setting range

(min. value | unit | max. value)

0.000

s

60.000

Subcodes

Lenze setting

Info

C01139/1

0.000 s

L_Transient_1

: Pulse duration

C01139/2

0.000 s

L_Transient_2

: Pulse duration

C01139/3

0.000 s

L_Transient_3

: Pulse duration

C01139/4

0.000 s

L_Transient_4

: Pulse duration

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01350 | ACDrive: Drive mode

Data type: UNSIGNED_8

Index: 23225

d

= 5AB9

h

Selection list

1 Speed mode
3 Torque mode

Subcodes

Lenze setting

Info

C01350/1

1: Speed mode

ACDrive: Drive mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising