5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 221

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

221

5

Motor control (MCTRL)

5.10

Encoder/feedback system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameterisation dialog in the »Engineer«

Short overview of the relevant parameters:

Parameter

Info

Lenze setting

Value Unit

Encoder selection / General settings

C00495

Speed sensor selection

• Source of feedback signal for speed control.

0: No sensor

C00490

Position encoder selection

From version 12.00.00

• Selection of the speed signal, the

dnMotorPosAct_p position signal is derived from.

0: no sensor: nSpeedSetValue_a

Settings for HTL encoder at DI1/DI2

C00115/1

Fkt. DI 1/2 10kHz

• Function of the digital inputs DI1 and DI2

0: DI1=In1 | DI2=In2

C00420/1

FreqIn12: Encoder increment

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

128 Inc/rev.

C00425/1

FreqIn12: Encoder scanning time

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

10 ms

C00497/1

FreqIn12: Encoder filter time

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

1.0 ms

C00496

Encoder evaluation method DigIn12 ( 224)

1: Low-resolution encoder

(StateLine)

C00055/1

Actual value - HTL encoder FreqIn12

- rpm

Monitoring

C00586

Resp. to encoder open circuit HTL

Encoder open-circuit monitoring ( 250)

1: Fault

Highlighted in grey = display parameter