Parameter list | C00480

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00480

C00481

C00482

Parameter | Name:

C00480 | LS_DisFree_b

Data type: UNSIGNED_8

Index: 24095

d

= 5E1F

h

The

LS_DisFree_b

SB: Display of the input values

Display area

(min. hex value | max. hex value)

0x00

0xFF

Value is bit-coded:

Info

Bit 0 bDis1

Signal level input bDis1 ... bDis8

... ...

Bit 7 bDis8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00481 | LS_DisFree

Data type: UNSIGNED_16

Index: 24094

d

= 5E1E

h

The

LS_DisFree

SB: Display of the input values

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Active

... ...

Bit 15 Active

Subcodes

Info

C00481/1

Input values wDis1 ... wDis4

C00481/...
C00481/4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00482 | LS_DisFree_a

Data type: INTEGER_16

Index: 24093

d

= 5E1D

h

The

LS_DisFree_a

SB: Display of the input values

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Info

C00482/1

Input values nDis1_a ... nDis4_a

C00482/...
C00482/4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100