Activate the password protection
The password protection is activated by setting a password.

How to set a password:

1. Enter the desired password in

C00505/3

.

• The password must have a length of 4 ... 16 characters.
• The password may consist of any character. However, this is not sensible.

Recommended characters are: lower case letters (a - z), upper case letters (A - Z) and

digits (0 - 9).

2. Execute "Set password" device command:

C00002/31

= "1: On / start"

• After successful execution, password status ON is displayed in

C00505/3

and password

protection takes immediate effect.

Temporarily deactivate the password protection
The "Check password" device command serves to temporarily deactivate the password protection

in order to execute password-protected functions.

• The password protection remains deactivated until

• an invalid password will be entered and checked

- or -

• the external 24-V supply of the control electronics is switched off (< 19 V).

How to temporarily deactivate the active password protection:

1. Enter the set password in

C00505/3

.

2. Execute "Check password" device command

C00002/32

= "1: On / start"

• After a successful check, password status OK is displayed in

C00505/3

.

Status displays

C00003

Status of the last device command

-

C00507/1

Password protection - all communication channels

• Bit coded display of the active protective functions:

-

Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection

Bit 3 ... 14 Reserved

Bit 15 Memory module binding on

Note:

As the password protection can be configured individually for each

single communication channel

from version 15.00.00

bit 1 and bit 2

indicate the active protection always with regard to the

communication channel used.