Parameter list | C01123

782

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01123

C01124

C01138

Parameter | Name:

C01123 | Sync window

Data type: UNSIGNED_16

Index: 23452

d

= 5B9C

h

From version 03.00.00

Time slot for monitoring the synchronisation signal or the phase position

• The synchronisation signal or the current phase position must be within this time slot around the corresponding

expected value (

C01122

).

• With the setting "1000 μs" there will be no monitoring.

Synchronisation of the internal time base

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

10000 100 μs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01124 | Sync correction width

Data type: UNSIGNED_8

Index: 23451

d

= 5B9B

h

From version 03.00.00

Correction increment for device synchronisation

• If the cycle times of the synchronisation signal differs and phase-locken loop (PLL) differ from each other, this

setting defines the measure the phase-locking loop is reset with.

• If synchronisation is not reached, select a higher correction constant.

• The optimum setting depends on quartz precision and must be determined empirically if required.

Synchronisation of the internal time base

Selection list

(Lenze setting printed in bold)

1 100ns
2 200ns
3 300ns
4 400ns

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01138 | L_Transient 1-4: Function

Data type: UNSIGNED_8

Index: 23437

d

= 5B8D

h

From version 04.00.00

Selection of edge evaluation
Selection list

0 High edge
1 Low edge
2 High and low edge

Subcodes

Lenze setting

Info

C01138/1

0: High edge

L_Transient_1

: Function

C01138/2

0: High edge

L_Transient_2

: Function

C01138/3

0: High edge

L_Transient_3

: Function

C01138/4

0: High edge

L_Transient_4

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1