14

Parameter change-over

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14

Parameter change-over

This function extension is only available from version 04.00.00!

For up to 32 freely selectable parameters, this basic function provides a change-over between four

sets with different parameter values.
The parameter list is created in the same way as the user menu is composed, namely by means of

parameterisation. In the »Engineer«, a user-friendly parameterisation dialog with import and

export functions is available for this purpose.

Motor data changeover

From version 12.00.00

, an optional changeover between four parameter sets with different motor

and control settings is supported in addition.
The optional motor data changeover is provided for applications/machines which have multiple

axes controlled successively but which do not require the simultaneous operation of multiple

motors. In this case, the very same controller can control the motors successively. Advantages of this

solution: Fewer components (controllers) and hence less energy consumption.

[14-1] Principle of the selective control of multiple motors using one controller

Motor data changeover

Motor changeover (e.g. via motor contactors)

Principle:

• The motor which is being controlled at the

moment is connected to the controller via

motor contactors. (The contactor system

can e.g. be controlled via the digital

outputs of the controller.)

• At the same time, the motor data

changeover serves to activate the motor

and control settings suitable for the motor

in the controller.

Note:

The motor data changeover is carried out

within 2 ms and hence within the opening and

closing times of most motor contactors.

M1

3~

M2

3~

M3

3~

M4

3~

Motordata parameterset 1

Motordata parameterset 2

Motordata parameterset 3

Motordata parameterset 4

1

0