C02215 | ls_writeparamlist: auto-dcb: threshold, C02216 | ls_writeparamlist: slip compensation, C02217 | ls_writeparamlist: imax in motor mode – Lenze 8400 StateLine User Manual

Page 791: C02215/1, C02215/2, C02215/3, C02215/4, C02216/1, C02216/2, C02216/3

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

791

15

Parameter reference

15.2

Parameter list | C02215

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02215

C02216

C02217

Parameter | Name:

C02215 | LS_WriteParamList: Auto-DCB: Threshold

Data type: UNSIGNED_16

Index: 22360

d

= 5758

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

rpm

60000

Subcodes

Lenze setting

Info

C02215/1

3 rpm

LS_WriteParamList

: c19_val1

C02215/2

3 rpm

LS_WriteParamList

: c19_val2

C02215/3

3 rpm

LS_WriteParamList

: c19_val3

C02215/4

3 rpm

LS_WriteParamList

: c19_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02216 | LS_WriteParamList: Slip compensation

Data type: INTEGER_16

Index: 22359

d

= 5757

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

-100.00

%

100.00

Subcodes

Lenze setting

Info

C02216/1

2.67 %

LS_WriteParamList

: c21_val1

C02216/2

2.67 %

LS_WriteParamList

: c21_val2

C02216/3

2.67 %

LS_WriteParamList

: c21_val3

C02216/4

2.67 %

LS_WriteParamList

: c21_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02217 | LS_WriteParamList: Imax in motor mode

Data type: UNSIGNED_16

Index: 22358

d

= 5756

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

A

655.35

Subcodes

Lenze setting

Info

C02217/1

47.00 A

LS_WriteParamList

: c22_val1

C02217/2

47.00 A

LS_WriteParamList

: c22_val2

C02217/3

47.00 A

LS_WriteParamList

: c22_val3

C02217/4

47.00 A

LS_WriteParamList

: c22_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising