Technology applications

7.3

TA "actuating drive speed (AC Drive Profile)"

326

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3.1

I/O assemblies

For the data exchange, the technology application supports the assembly output object instance 23

(0x17) and assembly input object instance 73 (0x49) defined by the ODVA (Open DeviceNet Vendor

Association).

Tip!
Detailed information on EtherNet/IP™ can be found at the web page of the ODVA (Open

DeviceNet Vendor Association) user organisation:

http://www.odva.org

Related topics:

Process data assignment for fieldbus communication

Run/Stop event

Scaling of speed and torque values

Instance 23 (0x17): Extended Speed and Torque Control Output

Bytes

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Net

Ref

NetCtrl

Fault

Reset

Run

Rev

Run

Fwd

1
2

Speed Reference (Low Byte)

3

Speed Reference (High Byte)

4

Torque Reference (Low Byte)

5

Torque Reference (High Byte)

Instance 73 (0x49): Extended Speed and Torque Control Input

Bytes

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

At

Reference

RefFrom

Net

CtrlFrom

Net

Ready

Running2

(Rev)

Running1

(Fwd)

Warning

Faulted

1

Drive State

2

Speed Actual (Low Byte)

3

Speed Actual (High Byte)

4

Torque Actual (Low Byte)

5

Torque Actual (High Byte)

Detailed information on the data transfer and "AC Drive Profile" can be found in the

E84AYCEO communication manual (EtherNet/IP™).