C00505 | password data, C00506 | pw protection internal config, C00505/3 – Lenze 8400 StateLine User Manual

Page 697: C00506/1, C00505/2, Ding binding id in, C00505/1, 15 parameter reference

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

697

15

Parameter reference

15.2

Parameter list | C00505

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00505

C00506

Parameter | Name:

C00505 | Password data

Data type: VISIBLE_STRING

Index: 24070

d

= 5E06

h

From version 06.00.00

Device access protection

Subcodes

Lenze setting

Info

C00505/1

MasterPin

C00505/2

Binding ID

C00505/3

Password

Read access  Write access  CINH  PLC-STOP  No transfer  COM  MOT

Character length: 16

Parameter | Name:

C00506 | PW protection internal config

Data type: UNSIGNED_16

Index: 24069

d

= 5E05

h

From version 15.00.00

Configuration of the password protection for device-internal parameter access

Individual password protection for single access channels

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Only access to user menu

The menus in the keypad are reduced. Only the user

menu can be used to change parameters.

Bit 1 Parameter write protection

Via system blocks (

LS_ParReadWrite1-6

and

LS_WriteParamList

), write/read parameters cannot be

written.

Bit 2 Parameter read protection

Via system blocks (

LS_ParReadWrite1-6

and

LS_WriteParamList

), write/read parameters cannot be

read.

Bit 3

Reserved

Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C00506/1

0x0007

PW protection internal config

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT