C00586 | resp. to open circuit htl encoder, C00588 | resp. to max. speed at switching freq, C00590 | resp. to switching frequency red – Lenze 8400 StateLine User Manual

Page 708: C00586, Is activated, C00590, C00588, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00586

708

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00586

C00588

C00590

Parameter | Name:

C00586 | Resp. to open circuit HTL encoder

Data type: UNSIGNED_8

Index: 23989

d

= 5DB5

h

Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00588 | Resp. to max. speed at switching freq.

Data type: UNSIGNED_8

Index: 23987

d

= 5DB3

h

Response if the maximum speed for the set inverter switching frequency is reached (

C00018

)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00590 | Resp. to switching frequency red.

Data type: UNSIGNED_8

Index: 23985

d

= 5DB1

h

Response to reduction of the inverter switching frequency (

C00018

)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1