C02874

C02875

Parameter | Name:

C02874 | PLI without motion

Data type: UNSIGNED_16

Index: 21701

d

= 54C5

h

From version 11.00.00

Pole position identification without motion

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 for SLPSM with controller enable
Bit 1 for SC PSM with mains on
Bit 2 for SC PSM with controller enable
Bit 3 for SC PSM once after fault reset
Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C02874/1

0x0001

PLI without motion

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02875 | PLI without motion: Adaptation of ident angle

Data type: INTEGER_8

Index: 21700

d

= 54C4

h

From version 11.00.00

Pole position identification without motion

Setting range

(min. value | unit | max. value)

-100

°

100

Subcodes

Lenze setting

Info

C02875/1

0 °

PLI without motion: Adaptation of ident angle

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1