3 data 1 ... data 4, Data 1 ... data 4, 11 system bus "can on board – Lenze 8400 StateLine User Manual

Page 528

Advertising
background image

11

System bus "CAN on board"

11.9

Parameter data transfer

528

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.9.2.3

Data 1 ... Data 4

Maximally 4 bytes are available for parameter value entries. Depending on the data format, they are

assigned as follows:

Example
A value of "123.45" is to be transmitted for a code, unit: "%" (e.g. C00039/1: "Fixed setpoint-JOG1").
In controllers of the 8400 series, parameters with the "%" unit have two decimal positions and hence

a scaling factor of "100".
Calculation:

• Value to be transmitted = scaling factor x value
• Data

(1 ... 4)

= 100 x 123.45 = 12345 (0x00 00 30 39)

Entries:

1st byte

2nd byte 3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Index

Subindex

Data 1

Data 2

Data 3

Data 4

LOW byte

HIGH

byte

LOW word

HIGH word

LOW byte

HIGH byte

LOW byte

HIGH byte

5th byte

6th byte

7th byte

8th byte

Parameter value (1 byte)

0x00

0x00

0x00

Parameter value (2 bytes)

0x00

0x00

LOW byte

HIGH byte

Parameter value (4 bytes)

LOW word

HIGH word

LOW byte

HIGH byte

LOW byte

HIGH byte

Note!

The "Factor" column of the

Table of attributes

contains a so-called scaling factor for all

Lenze parameters. The scaling factor is relevant to the transfer of parameter values

which have one or more decimal positions in the parameter list.
If the scaling factor is > 1, the value must be multiplied by the indicated scaling factor

prior to transmission to be able to transfer the value as an integer. At the SDO client end,

the integer must be divided by the scaling factor to obtain the original value including

decimal positions again.

1st byte

2nd byte 3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Index

Subindex

Data 1

Data 2

Data 3

Data 4

0x39

0x30

0x00

0x00

Advertising