Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

391

8

Basic drive functions (MCK)

8.1

Basic signal flow

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.1

Basic signal flow

The Motion Control Kernel is connected between setpoint generator (e.g. ramp generator, PID

process controller, etc.) and the motor control function in the case of the available technology

applications. For problem-free interaction of the Motion Control Kernel and motor control function,

the two associated system blocks

LS_MotionControlKernel

and

LS_MotorInterface

have interfaces

with corresponding inputs/outputs. These are visible in the FB Editor for monitoring purposes and

must be connected to each other:

[8-1]

Interconnection of Motion Control Kernel and motor control function