3.8

Commissioning of the "Switch-off positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.8

Commissioning of the "Switch-off positioning" technology application

[3-2]

Block diagram for wiring of the commissioning example for the "Switch-off positioning" application

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 45)

System constellation

X4/RFR

Controller enable

X4/DI1

Initiator connection for stop function 1

X4/DI2

Initiator connection for stop function 2

X4/DI3

Quick stop for CW rotation / selection of switch-off position 1

X4/DI4

Quick stop for CCW rotation / selection of switch-off position 2

X6

Diagnostic interface for connecting the USB diagnostic adapter

8400 StateLine

X61

X6

DIAG

AR A1U GA

X3

24I RFR DI1 DI2

X4

DI3 DI4

U V W

X6

t [s]

0
1

QSP

Cw

Ccw

-

DI1

DI2

DI1

DI2

v [m/s]

C00039/3

C00012

C00012

C00013

C00039/3

C00013

Cw
Ccw

Cw

Ccw

M

3~

i

0
1

0
0

1

1

Advertising