C00189

C00190

C00191

Parameter | Name:

C00189 | Resp. to too frequent AutoFailReset

Data type: UNSIGNED_8

Index: 24386

d

= 5F42

h

Response to exceeding the maximum number of "AutoFailReset" processes set in

C00186

.

AutoFailReset function

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00190 | L_NSet_1: Setpoint arithmetic

Data type: UNSIGNED_8

Index: 24385

d

= 5F41

h

The

L_NSet_1

FB: Selection of arithmetics

• To be able to influence the main setpoint (NSet) by an additional setpoint (NAdd).

Selection list

(Lenze setting printed in bold)

0 Out = Set
1 Out = Set + Add
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 Out = (Set*100%)/(100%-Add)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00191 | Logbook access index User

Data type: UNSIGNED_8

Index: 24384

d

= 5F40

h

From version 12.00.00

Logbook read interface

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C00191/1

255

Logbook access index User

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1