background image

15

Parameter reference

15.2

Parameter list | C02840

824

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02840

C02841

C02842

C02843

Parameter | Name:

C02840 | CountIn1: Parameter

Data type: UNSIGNED_32

Index: 21735

d

= 54E7

h

From version 03.00.00

Starting and comparison value for digital counting input

Using DI1 as counting input

Setting range

(min. value | unit | max. value)

0

Incr.

2147483647

Subcodes

Lenze setting

Info

C02840/1

0 incr.

CountIn1: Starting value

C02840/2

65535 incr.

CountIn1: Comparison value

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02841 | CountIn1: Counter content

Data type: UNSIGNED_32

Index: 21734

d

= 54E6

h

From version 03.00.00

Display of the current counter content of the digital counting input

Using DI1 as counting input

Display range

(min. value | unit | max. value)

0

Incr.

2147483647

Subcodes

Info

C02841/1

CountIn1: Counter content

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02842 | FreqInxx: Offset

Data type: INTEGER_16

Index: 21733

d

= 54E5

h

From version 03.00.00

Offset for digital frequency input

Using DI1 and DI2 as frequency inputs

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C02842/1

0.00 %

FreqIn12: Offset

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02843 | FreqInxx: Gain

Data type: INTEGER_16

Index: 21732

d

= 54E4

h

From version 03.00.00

Gain for digital frequency input

Using DI1 and DI2 as frequency inputs

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C02843/1

100.00 %

FreqIn12: Gain

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising