14 parameter change-over – Lenze 8400 StateLine User Manual

Page 585

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

585

14

Parameter change-over

14.3

Configuring the motor data parameter list by means of parameterisation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.3

Configuring the motor data parameter list by means of parameterisation

The setting of the values for value sets 1 ... 4 of the motor data parameter list can also be carried out

directly via the codes from code

C02210

(see following table; columns 1st value ... 4th value).

• Unlike the "definable" parameter list, the motor data parameter list has a fixed assignment to

the motor and control parameters.

• The preset values for value sets 1 ... 4 correspond to the Lenze setting of the respective motor or

control parameter.

• The values are entered according to the scaling format / scaling factor of the respective motor

or control parameter.

Code

Name

Lenze setting

1st value

2nd value

3rd value

4th value

C00006

Motor control

6

C02210/1

C02210/2

C02210/3

C02210/4

C00015

VFC: V/f base frequency

50.0 Hz

C02212/1

C02212/2

C02212/3

C02212/4

C00016

VFC: Vmin boost

1.60 %

C02213/1

C02213/2

C02213/3

C02213/4

C00018

Switching frequency

2

C02214/1

C02214/2

C02214/3

C02214/4

C00019

Auto-DCB: Threshold

3 rpm

C02215/1

C02215/2

C02215/3

C02215/4

C00021

Slip comp.

2.67 %

C02216/1

C02216/2

C02216/3

C02216/4

C00022

Imax in motor mode

47.00 A

C02217/1

C02217/2

C02217/3

C02217/4

C00023

Imax in generator mode

100.00 %

C02218/1

C02218/2

C02218/3

C02218/4

C00036

DC braking: Current

50.00 %

C02219/1

C02219/2

C02219/3

C02219/4

C00070/1

SLVC: Vp speed controller

15.00

C02220/1

C02220/2

C02220/3

C02220/4

C00070/2

Reserved

6.00

C02220/5

C02220/6

C02220/7

C02220/8

C00070/3

SLPSM: Vp speed controller

3.00

C02220/9

C02220/10

C02220/11

C02220/12

C00071/1

SLVC: Ti speed controller

100.0 ms

C02221/1

C02221/2

C02221/3

C02221/4

C00071/2

Reserved

50.0 ms

C02221/5

C02221/6

C02221/7

C02221/8

C00071/3

SLPSM: Ti speed controller

100.0 ms

C02221/9

C02221/10

C02221/11

C02221/12

C00072

SC: Tdn speed controller

0.00 ms

C02222/1

C02222/2

C02222/3

C02222/4

C00073/1

VFC: Vp Imax controller

0.25

C02223/1

C02223/2

C02223/3

C02223/4

C00073/2

SLVC: Vp torque controller

1.25

C02223/5

C02223/6

C02223/7

C02223/8

C00074/1

VFC: Ti Imax controller

65 ms

C02224/1

C02224/2

C02224/3

C02224/4

C00074/2

SLVC: Ti torque controller

30 ms

C02224/5

C02224/6

C02224/7

C02224/8

C00075

Vp current controller

7.00 V/A

C02225/1

C02225/2

C02225/3

C02225/4

C00076

Ti current controller

10.61 ms

C02226/1

C02226/2

C02226/3

C02226/4

C00079/1

SC: Current controller - feedforward control

0

C02229/1

C02229/2

C02229/3

C02229/4

C00079/2

SC: adapt. field weak. controller

1

C02229/5

C02229/6

C02229/7

C02229/8

C00079/3

SC: n-Ctrl Anti-Wind-Up

0

C02229/9

C02229/10

C02229/11

C02229/12

C00080

Override point of field weakening

0 Hz

C02230/1

C02230/2

C02230/3

C02230/4

C00081

Rated motor power

11.00 kW

C02231/1

C02231/2

C02231/3

C02231/4

C00082

Motor rotor resistance

276 mOhm

C02232/1

C02232/2

C02232/3

C02232/4

C00084

Motor stator resistance

330 mOhm

C02233/1

C02233/2

C02233/3

C02233/4

C00085

Motor stator leakage inductance

3.50 mH

C02234/1

C02234/2

C02234/3

C02234/4

C00087

Rated motor speed

1460 rpm

C02236/1

C02236/2

C02236/3

C02236/4

C00088

Rated motor current

21.00 A

C02237/1

C02237/2

C02237/3

C02237/4

C00089

Rated motor frequency

50 Hz

C02238/1

C02238/2

C02238/3

C02238/4

C00090

Rated motor voltage

400 V

C02239/1

C02239/2

C02239/3

C02239/4

C00091

Motor cosine phi

0.85

C02240/1

C02240/2

C02240/3

C02240/4

C00092

Motor magnetising inductance

81.0 mH

C02241/1

C02241/2

C02241/3

C02241/4

C00095

Motor magnetising current

8.50 A

C02242/1

C02242/2

C02242/3

C02242/4

C00106

Auto-DCB: Hold time

0.500 s

C02244/1

C02244/2

C02244/3

C02244/4

C00107

DC braking: Hold time

999.000 s

C02245/1

C02245/2

C02245/3

C02245/4

C00120

Setting of motor overload (I²xt)

100.00 %

C02246/1

C02246/2

C02246/3

C02246/4

C00234

Oscillation damping influence

5.00 %

C02249/1

C02249/2

C02249/3

C02249/4

Advertising