I/O terminals

6.3

Configuring exception handling of the output terminals

288

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3

Configuring exception handling of the output terminals

This function extension is only available from version 04.00.00!

Exception handling for the analog and digital output terminals in the event of an error can be set

via decoupling configuration and decoupling values.

• Bit coded selection is carried out in

C00441

for the analog output terminal, defining the events

that will trigger decoupling.

• Bit coded selection is carried out in

C00447

for the digitale output terminal, defining the events

that will trigger decoupling.

Finally, the following parameters define the value/status that the output terminals are to have

when they are decoupled:

Related topics:

Configuring exception handling of the CAN PDOs

( 522)

Bit

Event

Bit 0  SafeTorqueOff
Bit 1  ReadyToSwitchOn
Bit 2  SwitchedOn
Bit 3  Reserved
Bit 4  Trouble
Bit 5  Fault
Bit 6  Reserved
Bit 7  Reserved
Bit 8  Reserved
Bit 9  Fail CAN_Management

Bit 10  Reserved
Bit 11  Reserved
Bit 12  Reserved
Bit 13  Reserved
Bit 14  Reserved
Bit 15  Reserved

Parameter

Info

Lenze setting

Value Unit

C00442/1

AOut1_U: Decoupling value

0.00 %

C00448

DigOut decoupling value

Bit coded