15 parameter reference, Terminal assignment of the control modes 10 – Lenze 8400 StateLine User Manual

Page 603

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

603

15

Parameter reference

15.2

Parameter list | C00007

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Terminal assignment of the control modes 10 ... 16

"Actuating drive speed" TA

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Change of direction of

rotation

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Activate manual DC-

injection braking (DCB)

Fixed setpoint 2/3

DI3

Activate manual DC-injection

braking (DCB)

Quick stop

Motor potentiometer:

Increase speed

CW rotation quick stop

DI4

Change of direction of rotation

Motor potentiometer:

Decrease speed

CCW rotation quick stop

A1U

Main speed setpoint (10 V ≡ 100 % reference speed)

O1U

Actual speed value (10 V ≡ 100 % reference speed)

DO1

Status "Drive is ready"

Relay output

Status "Error is pending"

TA "actuating drive speed (AC Drive Profile)"

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Change of direction of

rotation

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Activate manual DC-

injection braking (DCB)

Fixed setpoint 2/3

DI3

Activate manual DC-injection

braking (DCB)

Quick stop

Motor potentiometer:

Increase speed

CW rotation quick stop

DI4

Change of direction of rotation

Motor potentiometer:

Decrease speed

CCW rotation quick stop

A1U

Local speed/torque setpoint (speed mode: 10 V ≡ 100 % reference speed; torque mode: 10 V ≡ 100 % M

max

)

O1U

Actual speed value (10 V ≡ 100 % reference speed)

DO1

Status "Drive is ready"

Relay output

Status "Error is pending"

"Switch-off positioning" TA

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Stop function 1

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Stop function 2

Selection: Pre-switch off 1

Fixed setpoint 2/3

DI3

Reset error message

CW rotation quick stop

Selection: Switch-off position 1

CW rotation quick stop

DI4

Change of direction of

rotation

CCW rotation quick stop

Selection: Switch-off position 2

CCW rotation quick stop

A1U

Main speed setpoint (10 V ≡ 100 % reference speed)

O1U

-

DO1

-

Relay output

-

Advertising