C02844

C02845

Parameter | Name:

C02844 | FreqIn12: Function

Data type: UNSIGNED_8

Index: 21731

d

= 54E3

h

From version 06.00.00

Output of the encoder position of the DI1/DI2 frequency input

Selection list

0 Loading with level
1 Loading with edge
2 Loading with level + reset

Subcodes

Lenze setting

Info

C02844/1

0: Loading with level

FreqIn12: PosIn function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02845 | FreqIn12: PosIn comparison value

Data type: INTEGER_32

Index: 21730

d

= 54E2

h

From version 06.00.00

Output of the encoder position of the DI1/DI2 frequency input

Setting range

(min. value | unit | max. value)

Lenze setting

0

Incr.

2147418112 0 incr.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1