C00985 | slvc: field current controller gain, C00986 | slvc: cross current controller gain, C00987 | inverter motor brake: nadd – Lenze 8400 StateLine User Manual

Page 771: C00988 | inverter motor brake: pt1 filter time, C00985, C00986, Can fu, Dy in, C00989, Which is ad

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

771

15

Parameter reference

15.2

Parameter list | C00985

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00985

C00986

C00987

C00988

C00989

Parameter | Name:

C00985 | SLVC: Field current controller gain

Data type: INTEGER_16

Index: 23590

d

= 5C26

h

Gain of the direct-axis current difference (Id) between setpoint and actual current for the voltage model of the

sensorless vector control (

SLVC

)

• The gain should be selected in a range of 0 ...1 %.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

20.00 0.50 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00986 | SLVC: Cross current controller gain

Data type: INTEGER_16

Index: 23589

d

= 5C25

h

Gain of the cross current difference for the voltage model of the sensorless vector control (

SLVC

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

20.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00987 | Inverter motor brake: nAdd

Data type: INTEGER_16

Index: 23588

d

= 5C24

h

From version 04.00.00

Speed lift which is connected in pulses to the brake rampe when the motor is braked.

Inverter motor brake

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

1000 80 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00988 | Inverter motor brake: PT1 filter time

Data type: INTEGER_16

Index: 23587

d

= 5C23

h

From version 04.00.00

PT1 filter time for smoothing the speed lift which is added in pulses (

C00987

)

Inverter motor brake

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

100.0 0.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00989 | Restart on the fly: Flying restart frequency fd_add

Data type: INTEGER_16

Index: 23586

d

= 5C22

h

From version 15.00.00

Flying restart fct.

Setting range

(min. value | unit | max. value)

0.00

Hz

5.00

Subcodes

Lenze setting

Info

C00989/1

0.00 Hz

Restart on the fly: Flying restart frequency fd_add

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100