Device control (DCTRL)

4.2

Device state machine and device states

92

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.8

TroubleQSP

This device status will be active as soon as a monitoring mode responds the error response

"TroubleQSP" has been parameterised for.

• The drive is decelerated to standstill with torque within the deceleration time parameterised for

quick stop independently of the defined setpoint and can be kept there.

• The device status can only be abandoned by acknowledging the error if the error cause is

removed.

• When the controller is inhibited, it is possible to jump to the "

SwitchedOn

" status even during

the error status since the controller inhibit function has a higher priority. As long as the error is

pending and has not been acknowledged, the status is changed back to the "TroubleQSP" status

when the controller is enabled afterwards.

Depending on certain conditions a status change takes place based on the "TroubleQSP" device

status.

Related topics:

wCANControl/wMCIControl control words

( 101)

Basics on error handling in the controller

( 420)

Error messages of the operating system

( 444)

"DRV-RDY" LED

"DRV-ERR" LED

Display in

C00137

Display in status word 1 (

C00150

)

Bit 11

Bit 10

Bit 9

Bit 8

TroubleQSP

1

0

0

1

Change condition

Changeover to the device status

Control bit "SwitchOn" of a control channel = "0".

ReadyToSwitchOn

Control bit "EnableOperation" of all control channels = "1"

AND terminal RFR = HIGH level (controller enable)

AND error is reset by the control bit "ResetFault"

AND no more errors are pending.

OperationEnabled

Control bit "EnableOperation" of a control channel = "0"

OR terminal RFR = LOW level (controller inhibit)

AND error is reset by the control bit "ResetFault"

AND no more errors are pending.

SwitchedOn

A message is active in the system.

Trouble