Basic drive functions (MCK)

8.4

Holding brake control

406

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.4.2.1

Operating mode

For different applications and tasks, different operating modes are available in

C02580

. The

selected operating mode determines whether the holding brake control is used and how the

holding brake will be switched.

Mode 0: Brake control off
In this mode, brake control is switched off (not active).

• The bMBrakeReleaseOut trigger signal for the holding brake control switching element is set to

FALSE.

• The bMBrakeReleased status signal is set to FALSE.

Mode 11: Manual control
In this mode, brake release and brake application can be directly controlled via the bMBrakeRelease

input without special logic or automatic.

• Setting pulse inhibit or controller inhibit has no influence on the bMBrakeReleaseOut trigger

signal for the holding brake control switching element.

• After the brake has been activated and the brake application time has expired, the controller is

inhibited automatically by the basic "Holding brake control" function.

Tip!
You can use mode 11 to easily check if the brake switches correctly.

C02589/1

Holding brake: Closing time

100 ms

C02589/2

Holding brake: Release time

100 ms

C02589/3

Holding brake: Waiting time status

100 ms

C02589/4

Holding brake: Ramp FF control

0 ms

C02593/1

Holding brake: Actual value monitoring

0.000 ms

C02593/2

Holding brake: Application delay

0.000 ms

C02610/1

MCK: Holding brake ramp time synchr.

2.000 s

C02607

Holding brake: Status

-

C00830/68

MCK: nMBrakeAddValue_a

- %

C00833/80

MCK: bMBrakeRelease

-

C00833/81

MCK: bMBrakeStartValue2

-

C00833/82

MCK: bMBrakeApplied

-