16.4

Reconfiguring the predefined interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6. Click Insert to insert the selected elements into the target interconnection as defined.

• Only possible if at least one element in the list has been selected for insertion.
• Insertion is also possible via the <Enter> button if at least one element is selected from

the list for insertion.

• The original layout and the relative position of the inserted blocks to each other are

maintained.

• When copying across the devices, you also insert the corresponding separate technical

objects (e.g. port definition).

• The inserted elements are deleted from the list. If the list is empty, the dialog box is

closed and the connections are inserted depending on the selected option.

7. If there are still elements to be entered in the list, repeat steps 5 and 6 until all elements are

inserted as intended.

8. Press Close to stop the insertion and close the dialog box.

• You can also use <Esc> or <Enter> to close the dialog box if "Insert" is not active.
• The elements inserted into the target interconnection so far are maintained.
• The connections for the blocks inserted so far are inserted depending on the selected

option.