C02289/1, C02289/2, C02289/3 – Lenze 8400 StateLine User Manual

Page 808: C02289/4, C02290/1, C02290/2, C02290/3, C02290/4, C02291/1, C02291/2

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02289

808

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02289

C02290

C02291

Parameter | Name:

C02289 | LS_WriteParamList: VFC-ECO: Minimum voltage U/f

Data type: INTEGER_16

Index: 22286

d

= 570E

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

20.00

%

100.00

Subcodes

Lenze setting

Info

C02289/1

20.00 %

LS_WriteParamList

: c977_val1

C02289/2

20.00 %

LS_WriteParamList

: c977_val2

C02289/3

20.00 %

LS_WriteParamList

: c977_val3

C02289/4

20.00 %

LS_WriteParamList

: c977_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02290 | LS_WriteParamList: VFC-ECO: Voltage reduction ramp

Data type: UNSIGNED_8

Index: 22285

d

= 570D

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.0

s

5.0

Subcodes

Lenze setting

Info

C02290/1

0.8 s

LS_WriteParamList

: c982_val1

C02290/2

0.8 s

LS_WriteParamList

: c982_val2

C02290/3

0.8 s

LS_WriteParamList

: c982_val3

C02290/4

0.8 s

LS_WriteParamList

: c982_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C02291 | LS_WriteParamList: SLVC: Field current controller gain

Data type: INTEGER_16

Index: 22284

d

= 570C

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

20.00

Subcodes

Lenze setting

Info

C02291/1

0.50 %

LS_WriteParamList

: c985_val1

C02291/2

0.50 %

LS_WriteParamList

: c985_val2

C02291/3

0.50 %

LS_WriteParamList

: c985_val3

C02291/4

0.50 %

LS_WriteParamList

: c985_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100