9

Diagnostics & error management

9.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.9.2

Structure of the 16 bit error number (bit coding)

This function extension is available from version 06.00.00!

In addition to the 32-bit error number, a 16-bit error number is generated if an error occurs. It

consists of the following information:

[9-2]

Structure of the error number

• Display parameter:

C00160

• The

LS_DriveInterface

system block shows the 16-bit error number at the output

wStateDetermFailNoShort.

• If the "Use 16BitFailNo." option is activated in

C00148

(bit 15 = "1"), the

LS_DriveInterface

system block also shows the short 16-bit error number at the output wStateDetermFailNoLow

(Low Word of the 32-bit error number

)

.

• The output wStateDetermFailNoHigh (High Word of the 32-bit error number) in this case is

"0".

• Advantage: The bus transfer of the error numbers is possible via a data word without

changing the interconnection of the technology application.

• For the sake of legibility, the 16-bit error number in the logbook is displayed with the following

syntax::
[Error subject area no.].[Error ID]

Error subject area

The error subject area indicates the internal "function unit" of the controller in which the error has

occurred.

Reserved

Error subject area

Error ID

2

1

0

8

14

Bit15

0

7

Note!

Due to the smaller value range (0 ...127), the number assignment to the error subject

area differs from the 32-bit error number.

Error subject area

Assigned errors

Remedy possible by

user?

No.

Name

11

Supply voltage

Errors that occur in connection with the supply voltage of the device. Yes

19

Temperature

Errors that occur for temperature reasons.

Yes

23

Motor management / encoder

Errors that occur within the motor control or encoder evaluation.

Yes

25

Analog I/O integrated

Errors that occur in connection with the analog inputs and outputs.

Yes

26

Defective device hardware

Errors that occur due to defective device hardware.

No

27

Extension module slot 1

Errors that are reported by the extension module, and

communication errors to the plugged-in extension module.

Yes if it is a fieldbus error.

31

CAN integrated (general)

Errors related to general CAN functions.

Yes