9diagnostics & error management – Lenze 8400 StateLine User Manual

Page 435

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

435

9

Diagnostics & error management

9.5

Logbook

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• Additionally, a read access to different individual elements of the logbook entry addressed can

be executed via the subcodes of

C00193

. These parameters have a uniform data format (32 bits)

and represent the most important part of the logbook data:

Basic workflow

Related topics:

Structure of the 32-bit error number (bit coding)

Parameter

Display

C00193/1

Response index, reference to the index requested (

C00191/1

)

C00193/2

Error activity flag (0 = error not active; 1 = error active)

C00193/3

Error counter (0 ... 255)

• This information depends on the logbook configuration. In the Lenze setting the logbook

configured so that identical errors do not produce a new line entry, but a counter is

incremented for this error.

C00193/4

Error type (bits 26 ... 29 of the

32-bit error number

)

C00193/5

Error subject area + error ID (bits 0 ... 25 of the

32-bit error number

)

C00193/6

Time in [s] during which the power was switched on (power-on time meter).

Note!

• In the case of a simultaneous read access to the logbook entry (

C00192/1

) and its

individual elements (

C00193/x

), the line index in

C00191/1

must only be reset by the

control after the read process is fully completed. Otherwise the data read are

inconsistent.

• Depending on the device version, the maximum number of logbook entries can vary:

• 8400 StateLine: 15 logbook entries
• 8400 HighLine/TopLine: 50 logbook entries

• The logbook can be read out by an external control or

visualisation via the procedure shown on the left.

• The "Response index" query ensures that the logbook entry

read really corresponds to the logbook entry requested.

:ULWH/RJOLQHLQGH[

&

5HDG/RJOLQH

&

/RJOLQH

UHVSRQVHLQGH[

/RJOLQH

LQGH["

1R

<HV

Advertising