Oscilloscope function

10.3

Operation

482

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3.6

Cursor function: Reading individual measured values

In addition to the zoom and scaling function, the oscilloscope offers a "cursor function" that can be

used to display individual measured values of a selectable channel or the difference between two

measured values.

How to use the cursor function:

1. Click the Cursor tab to display it in the foreground and activate the cursor function.

• Now two movable vertical measuring lines are shown in the oscillogram.

2. Select the channel for which individual measured values are to be indicated from Channel

list field.

3. Hold down the left mouse button and drag the red vertical measuring line to the desired

position.

• The active measuring line is represented by a continuous line, the inactive measuring

line is represented by a dashed line.

• If you position the mouse pointer over the inactive measuring line, the measuring line

automatically becomes active.

• The value measured at the position of the active measuring line is indicated in the Value

group box.

• The difference between the values measured at the two measuring lines is indicated in

the Difference group box.

• Comparing peak values: Several values displayed in the oscillogram can be compared by

means of a horizontal measurement line. This measurement line is automatically

generated based on the current cursor position and thus cannot be moved separately.