467

9

Diagnostics & error management

9.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

dF26: Appl. watchdog [xx.0145.00026]

dF21: BU watchdog [xx.0145.00033]

dF22: CU watchdog [xx.0145.00034]

dF10: AutoTrip reset [xx.0145.00035]

dF50: Retain error [xx.0145.00050]

dF51: CuCcr error [xx.0145.00051]

Response (Lenze setting printed in bold)

Setting:

C00580/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Time-out of the application. The required computing

time of the application exceeds the available computing

time.

Reduction of the function block interconnection or the

complexity of the application.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

Setting:

C00189

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Too frequent auto-trip reset.

• Check the error cause that activates the auto-trip

reset.

• Eliminate error cause and reset (acknowledge) error

manually afterwards.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

An error has occurred when accessing retain data.

• Either caused by an internal hardware error or by lack

of mains switching after a firmware download.

Mains switching

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Mains switching

• Please contact Lenze if the problem occurs again.

Advertising